Perfect voltage
at lofty heights:
Our MPC Series.

There’s more to be found behind the acronym MPC than just MULTI Pitch CONTROLLER. We also offer DGNR and DCTransD converters, the latter even featuring a controlled emergency shutdown. That said, we are committed to offering the latest converter technology for optimal reliability. Hence the development of the MPC Series. Their quality is a result of our own development and production expertise. And that eight times over.
 
The MPC Series is in fact an entire family of converters. And similar to any family, it includes converters big and small. That means four AC variants with an output from 20 A to 75 A. Add to that four DC variants with an output from 30 A to 125 A. If you’re looking for a catch, you’re right: there’s more than meets the eye when it comes to our converters:

The application features
of the MPC Series:

  • MULTI Pitch CONTROLLER with actual speed value feedback
  • Positioning control can be activated
  • Actual speed value generation via sine/cosine signals
  • Speed control in closed-loop and open-loop mode
  • High-priority emergency operation in feathering position as an open loop
  • Heavy-duty for activation of a defined current/time profile

The technical features 
of the MPC Series:

  • 4 AC variants (20 A, 35 A, 55 A, 75 A)
  • 4 DC variants (30 A, 60 A, 75 A, 125 A)
  • Integrated positioning card for signal conditioning and analysis
  • BatteryPitchProfile and BatteryBrakeChopper
  • Usable from -40 °F to +158 °F
  • Interfaces: USB, 2 x RS485, CANopen (others possible via Busmaster)
  • Additional inputs: 12 digital, 4 analog
  • Additional outputs: 8 digital

AC variants:

Device MPC 20 AC MPC 35 AC MPC 55 AC MPC 75 AC
Grid connection 230 V AC -20 % bis 440 V AC +10 %; -20 %, 50/60Hz
DC bus connection 100 V ... 620 V DC
Output voltage AC 3~0 ... 400 V
Continuous current 20 A 35 A 55 A 75 A
Peak current (min. 6 s) 40 A 70 A 110 A 150 A
Rated power @ 400 V 13 kVA 24 kVA 38 kVA 52 kVA
Short-time 27 kVA 48 kVA 76 kVA 104 kVA

DC variants:

Device MPC 30 DC MPC 60 DC MPC 75 DC MPC 125 DC
Grid connection 230 V AC -20 % bis 440 V AC +10 %; -20 %, 50/60Hz
DC bus connection 100 V ... 620 V DC
Output voltage DC+/- 0 ... 400 V
Continuous current 30 A 60 A 75 A 125 A
Peak current (min. 6s.) 60 A 120 A 150 A 250 A
Rated power @ 400 V 12 kW 24 kW 30 kW 50 kW

Short-time

24 kW 48 kW 60 kW 100 kW